  protected by dustproof cap! field measuring instruments clamp on ac/dc hitester sensor common specifications cable length: 2m (6.56 ft) maximum circuit voltage: 600v applicable standards: safety: en61010-2-032:1995, cat iii 600v, pollution class 2, emc: en61326:1997+a1:1998+a2:2001 3290, 3290 -10 9693 specifications effect of conductor position: 0.7% or less effect of external magnetic field: equivalent to 2 a or less (in 400a/m external magnetic field) external dimensions: approx. 62w(2.44") 196h(7.72") 35d(1.38") mm weight: approx. 500 g(17.6oz.) 2000a 55mm (2.17") 9692 specifications effect of conductor position: 0.5% or less effect of external magnetic field: equivalent to 0.7 a or less (in 400a/m external magnetic field) external dimensions: approx. 62w(2.44") 167h(6.57") 35d(1.38") mm weight: approx. 410 g(14.5oz) 200a 33mm (1.3") 9691 specifications effect of conductor position: 1.0% or less effect of external magnetic field: equivalent to 0.5 a or less (in 400a/m external magnetic field) external dimensions: approx. 53w(2.09") 129h(5.08") 18d(0.71") mm weight: approx. 230 g(8.1oz) 100a 35mm (1.38") 3290 -10 functions current integral measurement (obtain polarity-speci? c integrated dc values) operating time/duty measurement current measurement at dc and from 1 hz ac, with comprehensive integrating functions independent sensors for convenient portable measuring * measurement cable can be up to 100m(328.1ft) long choice of three sensors: 20, 200 and 2000 a ranges choice of measurement modes: dc, ac+dc, ac and peak choice of recording outputs: rms, waveform, frequency and integral value choice of response times: switches in three steps filter function: fc = 550 hz to suppress undesired harmonics
1 enhanced low-frequency current measurement analysis capabilities measures current from 1 hz, such as that used for inverter motor control. inverter motor current and rms waveforms are recorded simultaneous ly. simultaneous recording of control signals is the best method for evaluating and analyzing such devices during product developme nt and maintenance. current recording data saved to pc card at worksite. after returning to the office, data can be analyzed and stored on a pc. * recording basic waveform component with 3290 filter function active * waveform and rms values can be recorded simultaneously (mon & rec mode) half-wave rectified waveform during operation (mon) rms current recording (rec) recording current consumption of a hair dryer pc card-compatible recorder control signal recording pc card-compatible recorder comprehensive basic current measurement functions of the 3290 all functions needed for measuring dc and ac current and distortion waveforms in a single instrument optional model 9400 carrying case stores everything together features ? ac+dc mode measures true rms current of full- and half-wave recti? ed waveforms and inverter output waveforms from 1 hz ? peak mode measures the maximum waveform amplitude of in-rush current at device startup ? maximum, minimum and mean value modes easily measure current variations in lines with severely ? uctuating loads ? simultaneous waveform and rms output enables rms and waveform or frequency ? uctuations to be externally recorded together ? selectable measurement response time enables setting the instrument response to suit changes in load current ? lpf (fc = 550 hz) ? lters out unnecessary harmonic currents and noise example of temperature sensitivity characteristics example of zero-point temperature characteristic (model 9693 sensor) clamp-on current sensor temperature characteristics * the hall-effect current detection element in each sensor has a speci? c zero-point temperature characteristic that manifests as deviation (scatter) 0.0 a combined dc and ac waveform 0.0 a half-wave recti? ed waveform 0.0 a full-wave recti? ed waveform measures rms properly in the ac+dc mode deviation [%] deviation [%] temperature [c] temperature [c] sensor used frequency range rated input measurement range max. display output terminal voltage normal measurement peak measurement 9691 dc to 10 khz (- 3 db) 100 a rms 150 a peak 20.00 a 25.00 a 50.0 a 100 mv/a 200.0 a 105.0 a 150.0 a 10 mv/a 9692 dc to 20 khz (- 3 db) 200 a rms 300 a peak 20.00 a 25.00 a 50.0 a 100 mv/a 200.0 a 210.0 a 300.0 a 10 mv/a 9693 dc to 15 khz (- 3 db) 2000 a rms 2840 a peak 200.0 a 250.0 a 500 a 10 mv/a 2000 a 2100 a 3000 a 1 mv/a current range table (common to 3290 and 3290- 10 ) - 3 - 2 - 1 0 1 2 3 - 4 0 - 2 0 0 2 0 4 0 6 0 8 0 9 6 9 1 9 6 9 2 9 6 9 3 - 4 . 0 - 2 . 0 0 . 0 2 . 0 4 . 0 - 4 0 - 2 0 0 2 0 4 0 6 0 8 0 n o . 1 n o . 2 n o . 3 n o . 4 n o . 5 - 3 - 2 - 1 0 1 2 3 - 4 0 - 2 0 0 2 0 4 0 6 0 8 0 9 6 9 1 9 6 9 2 9 6 9 3 - 4 . 0 - 2 . 0 0 . 0 2 . 0 4 . 0 - 4 0 - 2 0 0 2 0 4 0 6 0 8 0 n o . 1 n o . 2 n o . 3 n o . 4 n o . 5
2 integral functions such as battery charging/discharging, integral ac current and repeat integral measurements are fully supported. in addition, the "operating time/rate" function shows the operating state of loads. comprehensive current integral functions of the 3290- 10 features ? polarity-speci? c integral function measures battery charging and discharging with one instrument (positive, negative and total integral values) ? operating time/rate display function measures load operating status (with settable threshold value) ? polarity-speci? c peak current display function measures peak battery charge and discharge current with one instrument ? repeat measurement and data storage function lets you easily conduct the same measurement up to 20 times and then save that data in the unit's memory. ? time-limited mean value display function shows the mean value within a speci? c integration time (can be used in combination with repeat measurement) ? external dc power capability enables long-term measurements under battery power speci? cation 3290 3290 -10 current measurement measurement modes dc, ac+dc, ac (rms/mean) dc, ac+dc, ac (rms) peak value display displays absolute value (of waveform peak) displays polarities independently (peak value of waveform, in dc mode) maximum/minimum value display displays maximum, minimum and mean values maximum and minimum values (in ac and ac+dc modes) ac ? lter function in ac and ac+dc modes, ? lter (fc = 550 hz) on/off dc ? lter function during dc and ac+dc waveform output, ? lter (fc = 1 hz) on/off during dc waveform output, ? lter (fc = 1 hz) on/off separate ac/dc output function separate output of ac content and dc content - output (connector 1) current waveform (2-v range)/rms current (2-v dc range) switchable output (connector 2) rms current/low-battery warning switch current integral value (selectable +, -, total, 1-v dc/range) integral measurement timer settings - 1 min. to 99 hours, 59 min (for repeated measurement up to 20 times) elapsed time display hours:minutes (up to 2000 hours) mean value time limit display mean value = integral value / integration time output (connector 1) selectable current waveform or rms current output (connector 2) current integral value (selectable +, -, total, 1-v dc/range) rate measurement rate - rate = operating time / total measurement time operating time measurement displayed operating time: hours:minutes (up to 2000 hours) frequency measurement range setting auto/manual ranging auto ranging output (connector 1) frequency value (1-v dc/range) - output (connector 2) rms current data storage - peak, maximum, minimum, mean value, integral value, operating time,rate bar graph display when dc center is zero, bar graph can display 10x magnification display of number of memorized data points display refresh rate n: twice/second, f: 4 times/second (3290- 10 is 10 times/second) , s: once/3 seconds * 3290- 10 dc mode is once/second measurement response time switching f: 0.2 s, n: 0.8 s, s: 8 s switching power supply battery and ac adapter battery, ac adapter, external battery (8.4 to 15.6 v dc) 3290/3290 - 10 function comparison 0.0 a operating time current threshold setting operating time a non-operating time b operating time e non-operating time d total measuring time (a+b+c+d+e) (measurement may be repeated up to 20 times) dc load current measurement + - positive integral negative integral total measuring time: z=(a+b+c+d+e) operating time: a+c+e rate (%): (a+c+e)/z 100 + peak value - peak value total integral value = positive integral + negative integral operating time c * integration interval can be up to 2000 hours dc load current measurement dc load current measurement sensor used current range integral range (5 ranges) measurement range 9691/9692 20 a 10.000 ah to 100.00 kah 0 to 210.0 kah (9691) 0 to 420.0 kah (9692) 200 a 100.00 ah to 1000.0 kah 9693 200 a 100.00 ah to 1000.0 kah 0 to 4200 kah 2000 a 1000.0 ah to 10000 kah current integral range table convenient repeat measurement function integral measurements during a speci? ed interval can be repeated continuously up to 20 times. integral and numerical measurement data values (maximum, minimum, mean and peak) plus operating time and duty are stored in internal memory. saved data can be recalled and veri? ed at any time.
head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@hiokiusa.com distributed by all information correct as of oct. 5, 2004. all speci?cations are subject to change without notice. 3290e3-4xb-05p printed in japan shanghai representative of?ce : 1704 shanghai times square of?ce 93 huaihai zhong road shanghai, 200021, p.r.china tel +86-21-6391-0090, 0092 fax +86-21-6391-0360 e-mail: info@hioki.cn 3 options 9691 clamp-on ac/dc sensor (100 a) 9692 clamp-on ac/dc sensor (200 a) 9693 clamp-on ac/dc sensor (2000 a) 9445- 02 ac adapter 9445- 03 ac adapter (eu) 9094 output cable 9400 carrying case 9199 connector adapter (bnc-to-banana [female]) measurement is not available with only the 3290 or 3290- 10 clamp-on ac/dc hitester . a clamp-on ac/dc sensor (model 9691, 9692 or 9693) must also be purchased separately. mode response time setting dc 1 < f < 10hz 10 < f < 45hz 45 < f < 66hz 1.8%rdg.10dgt. 1.8%rdg.5dgt. fast nomal slow fast nomal range 2000 a 66hz < f < 1khz slow 1.3%rdg.8dgt. 2.3%rdg.8dgt. 2000 a 1.3%rdg.3dgt. 2.3%rdg.3dgt. 200.0 a 200.0 a ac mean (only 3290) 2.3%rdg.8dgt. 1.8%rdg.12dgt. (when ac + dc is set only) 1.3%rdg.8dgt. 2.3%rdg.8dgt. 200.0 a 2.3%rdg.3dgt. 1.3%rdg.3dgt. 2.3%rdg.3dgt. 1.8%rdg.7dgt. (when ac + dc is set only) 2000 a ac+dc ac rms dc combined accuracy with 9693 measurement frequency f mode response time setting dc 1 < f < 10hz 10 < f < 45hz 45 < f < 66hz dc 1.3%rdg.10dgt. 1.3%rdg.5dgt. ac+dc ac rms fast nomal slow fast nomal 66hz < f < 1khz range 20.00 a 200.0 a 20.00 a 200.0 a slow ac mean (only 3290) 20.00 a 1.3%rdg.8dgt. 2.3%rdg.8dgt. 200.0 a 1.3%rdg.3dgt. 2.3%rdg.3dgt. measurement frequency f combined accuracy with 9691 or 9692 model 3290 and 3290- 10 specifications (accuracy guaranteed at 23 5c(73 9f), 80% rh or less, non-condensating) period of guaranteed accuracy: 1 year 1.3%rdg.12dgt. (when ac + dc is set only) 1.3%rdg.8dgt. 1.3%rdg.8dgt. 2.3%rdg.8dgt. (9691: up to 500hz) 1.3%rdg.7dgt. (when ac + dc is set only) 1.3%rdg.3dgt. 1.3%rdg.3dgt. 2.3%rdg.3dgt. (9691: up to 500hz) output rate: (1) rms current (rec_a): 2 v dc/range; (2) current waveform (mon): 2 v/range; (3) frequency (rec_hz) *1 : 1 v dc/range (*1. 3290 only) combined output connectors (out1 & out2 *2 ): (1) current waveform (mon / mon.fl *1 ) & rms current (rec); (2) current waveform (mon / mon.fl *1 ) & low-battery detection (b.lo) (3) rms current (rec) & low-battery detection (b.lo) (4) frequency (rec) & rms current (rec) (3290 only) *1. mon.fl is with fc = 1 hz filter on, *2. out2 of the 3290- 10 is total integral value (ah), selected from positive, negative or total value operating temperature and humidity: 0 to 40c (32 to 104f) @80% rh or less (non-condensating) storage temperature: -10 to 50c (14 to 122f) (non-condensating) operating environment: up to 2000m asl, indoors power source: four aa-size (lr6) alkaline batteries, or ac adapter model 3290- 10 also accepts 8.4 to 15.6 v external dc power max. power consumption: 500 mva (using batteries) battery life: approx. 22h (continuous operation) applicable safety standards emc: en61010-1:2001, en61326:1997+a1:1998+ a2:2001, en61000-3-2:2000, en61000-3-3:1995+a1:2001 external dimensions, weight: approx. 155w (6.10") 98h (3.86") 47d (1.85") mm, approx. 545 g (19.2oz.) supplied accessories: carrying strap (1), aa-size (lr6) alkaline batteries (4) provided functions zero adjustment (dc and ac+dc) data hold setting saving function:saves the state of settings key lock battery check auto power off: about 10 minutes after last key operation, beeper warning available beeper sound on/off temperature characteristic: 0.1 specified accuracy/c (@0 to 40c) (0.18 specified accuracy/f (@32 to 104f)) function display: 21-segment bar graph, over-range (o.l.), low-battery warning (b), hold (hold), auto power off (aps) measurement response time: (1) fast (0.2 s) for 45+ hz; (2) normal (0.8 s) for 10+ hz); (3) slow (8.0 s) for 1+ hz) * input: the time for analog output to stabilize after transition from 0 r 90% or from 100 r 10%, setting ac (rms) or ac+dc display refresh rate: (1) normal: twice per second; (2) slow: once per three seconds; (3) fast: four times per second (ten times per second for 3290- 10 ; (4) bar graph display: 4 times per second zero suppression: 5 counts range switching: auto/manual crest factor: 2.5 or less, or the same or less than peak value of connected sensor output impedance: 100 or less 2.0%rdg.3dgt. (when ac + dc, slow is set only) 2.0%rdg.8dgt. (when ac + dc, slow is set only) 3.0%rdg.3dgt. (when ac + dc, slow is set only) 3.0%rdg.8dgt. (when ac + dc, slow is set only) frequency range (accuracy range) maximum display accuracy 10.00hz (1.00 to 10.00hz) 12.50hz 100.0hz (10.0 to 100.0hz) 125.0hz 1000hz (100 to 1000hz) 1000hz 1.0%rdg.1dgt. 0.3%rdg.1dgt. 3290 -10 speci?cations accuracy integral value display current measurement accuracy 1 dgt measurement time not more than 0.2 s deviation per hour (@23c(73f)) output connector voltage display accuracy 2 mv extension cables available by special order connects from the standard 2m (6.52ft) sensor cable to the 3290 or 3290-10 (available lengths are 5, 10, 20, 30, 50 and 100m (16.4, 32.8, 65.6, 98.4, 164.1 and 328.1ft))